SCB13
Product name :SCB13 Series Close Loop Hall Current Sensor
product model:SCB13-300A, SCB13-400A,SCB13-500A,SCB13-600A
Series: SCB13
Ipn: 300A~600A
Diameter: 40mm
SCB 13 Series Close Loop Hall Current Sensor is a new generation closed loop current sensor based on Hall effect principle, it can accurately measure DC, AC and pulse current and other various irregular Waveforms current in electrical isolation conditions. Perforations in the form of a square type, use for copper connections, it is widely used in inverters, power supply, DC panel and welding machines etc. Products potting adapt imported resin, which has excellent thermal conductivity and scalability. High-performance core result minimal residual magnetism, all electronic is imported components assembled, along with excellent circuit design, all products processed via 48 hours normal temperature aging and eight hours high temperature aging, and by rigorous factory testing, it has excellent characteristics with long-term stable operation even in harsh working conditions. Good function in temperature compensation.
Technical Data:
Parameters(25°C) Model | SCB13- | |||||||
I | V | I | V | I | V | I | V | |
300A | 400A | 500A | 600A | |||||
Nominal Rms Current (Ipn) | ±300AT | ±400AT | ±500AT | ±600AT | ||||
Measuring Range (Ip) | 600AT | 700AT | 800AT | 900AT | ||||
Turns Ratio | 1:3000 | 1:4000 | 1:5000 | 1:5000 | ||||
Road Resistance Rmax | 40KΩ | 50KΩ | 75KΩ | 75Ω | ||||
Output | ±100mA | ±4V | ±100mA | ±4V | ±100mA | ±4V | ±100mA | ±4V |
Measuring Resistance | 20~25Ω | ≥10KΩ | 20~25Ω | ≥10KΩ | 20~25Ω | ≥10KΩ | 20~25Ω | ≥10KΩ |
Working voltage | DC ±15V (±5%) | |||||||
Accuracy @ Ta=25°C | ±0.5% FS | |||||||
Linearity @ Ta=25°C | ±1% FS | |||||||
Offset Current/Voltage | <±0.2mA <±10mV | |||||||
Offset temperature characteristics | < ±0.02%/°C | |||||||
Thermal drift of Vo | <±1mV/°C (If=0) | |||||||
Bandwidth | DC ~150kHz | |||||||
Response time | < 1uS | |||||||
Hysteresis offset | I: < 0.5mA V: <20mV (if=F.S. 0<--->Nominal RMS Current) | |||||||
Withstand voltage | 3kVrms/50Hz/min | |||||||
Current consumption | 13mA (No-load current) + output current (secondary) | |||||||
Operating temperature | -20~+80 °C | |||||||
Storage temperature | -40~+85 °C |

Instructions
1. SCB13 Series is divided into voltage output and current output, the current output does not have GIN regulation.
2. Round perforation, mainly measure cable conductor current.
3. Galvanic isolation between primary and secondary circuit provides accurate electronic measurement of DC, AC or pulse currents.
4. Advantages: Wide bandwidth, excellent accuracy, good linearity and fast response.
Caution: Incorrect wiring may damage the sensor